selected publications
-
academic article
- Simultaneous Upward Lightning From Small Structures and From the 150 m High Peissenberg Tower, Germany. IEEE Transactions on Electromagnetic Compatibility. 64:1198-1205. 2022
- High-Speed Video Observation, Currents, and EM-Fields From Four Negative Upward Lightning to the Peissenberg Tower, Germany. IEEE Transactions on Electromagnetic Compatibility. 63:803-810. 2021
- Field Enhancement by Lightning Strikes to Tall Tower Versus Lightning Strikes to Flat Ground. IEEE Transactions on Electromagnetic Compatibility. 63:550-557. 2021
- Performance of the European Lightning Detection Network EUCLID in Case of Various Types of Current Pulses From Upward Lightning Measured at the Peissenberg Tower. IEEE Transactions on Electromagnetic Compatibility. 62:116-123. 2020
- Share of the Lightning Current on Electric Installation Lines Within a Building Considering Equipotential Bonding at Roof Level. IEEE Transactions on Electromagnetic Compatibility. 2019
- Electric Field Characteristics of Subsequent Return Strokes, M-Components, and ICC-Pulses From Negative Upward Lightning Measured at the Peissenberg Tower. IEEE Transactions on Electromagnetic Compatibility. 61:1138-1146. 2019
- Properties of Three Types of M-Components and ICC-Pulses From Currents of Negative Upward Lightning Measured at the Peissenberg Tower. IEEE Transactions on Electromagnetic Compatibility. 60:1825-1832. 2018
- Some Return Stroke Characteristics of Negative Lightning Flashes Recorded at the Peissenberg Tower. IEEE Transactions on Electromagnetic Compatibility. 59:1490-1497. 2017
- Transient Response of the Top Structure of the Peissenberg Tower to Lightning. IEEE Transactions on Electromagnetic Compatibility. 57:1547-1555. 2015
- Characteristics of Upward Positive Lightning Initiated From the Peissenberg Tower, Germany. IEEE Transactions on Electromagnetic Compatibility. 57:102-111. 2015
- The Slow-Varying Electric Field of Negative Upward Lightning Initiated by the Peissenberg Tower, Germany. IEEE Transactions on Electromagnetic Compatibility. 55:353-361. 2013
- Measurement of Magnetic Fields Inside Single- and Double-Layer Reinforced Concrete Buildings During Simulated Lightning Currents. IEEE Transactions on Electromagnetic Compatibility. 46:208-221. 2004
- Laboratory simulation of direct lightning strokes to a modeled building: measurement of magnetic fields and induced voltages. Journal of Electrostatics. 60:223-232. 2004
-
chapter
- Current and Electric Field Characteristics of 35 Return Strokes from Negative Lightning Measured at Peissenberg Tower Germany. Lecture Notes in Electrical Engineering. 2019
-
conference paper
- LLS Detection for Negative First and Subsequent Return Strokes Measuredat Peissenberg Tower Germany. . 2019
- Currents on Electric Installation Lines in Case of Equipotential Bonding at Roof Level. . 2018
- Three Types of M-Components and ICC-Pulses and their Characteristics obtained from Negative Upward Lightning Measured at Peissenberg Tower. . 2018
- Currents on electric installations inside of buildings in case of lightning equipotential bonding at the roof. . 2017
- On the origin of the lightning current oscillation measured at the Peissenberg Tower, Germany. . 2016
- Self-initiated and other-triggered positive upward lightning measured at the Peissenberg Tower, Germany. . 2014
- Upward positive lightning measured at the Peissenberg Tower, Germany. . 2013
- The electric field of negative upward lightning strikes at the Peissenberg tower, Germany. . 2012